POWERBUILD STATIONARY TUBULAR BATTERIES
         
Special Lead Alloy Encompass Virgin Active Materials Auto Controlled Electrodes Formation  
Ultra Low Maintenance Auto Heat Sealing Assembly Line  
Quality and Reliability-Electrical and Chemical Lab. Own Engineering Solutions  
Automated Casting Section Own Container And cover Plants  
         
 
Our Cell
Designation
Capacity at 10 Hr Rate as per IS 1651 Table 3
Overall Dimension
L
+ 5 TOL
W
+ 5 TOL
H
+ 15 TOL
Weight (Approx.)
With
Acid
Without
Acid
First Charge Current
Recharge Current
Upto
2.4 VPC
Till Full
Charge
1 2
3 4 5
6 7
8
9 10
  AH
mm mm mm
Kgs. Kgs.
A
A A
PBS 20
PBS 40
PBS 60
PBS 80
PBS 100
PBS 120
PBS 150
PBS 200
PBS 300
PBS 400
PBS 500
PBS 600
PBS 700
PBS 800
PBS 900
PBS 1000
20
40
60
80
100
120
150
200
300
400
500
600
700
800
900
1000
95 165 275
95 165 275
95 165 275
145 170 280
145 170 440
145 170 440
145 170 440
215 185 485
215 185 485
265 210 485
265 210 515
265 210 535
305 220 700
305 220 700
305 220 700
305 220 700
6 4.0
6.9 5.0
7.6 6.0
11.1 7.8
15.6 10.5
15.9 11.1
17.5 13.3
27 20
37 28
49 38
57 41
64 45
74 52
84 60
94 67
105 75
1
2
3
4
5
6
7.5
10
15
20
25
30
35
40
40
50
2 1
4 2
6 3
8 4
10 5
12 6
15 7.5
20 10
30 15
40 20
50 25
60 30
70 35
80 40
90 45
100 50
 
NOTE
01 Filling Sp.gr. of sulphuric Acid at 27 deg C : 1.190
02 Final Sp.gr. of Sulphuric Acid after full } : 1.200
charge at 27 Deg C } +/-0.005
03 Duration of First Charge : 100 hrs. (Approx.)
04 Duration of Recharge in two steps : 15 hrs. (Approx.)
05 'AH' capacity indicated is at 10 hrs. Discharge rate at 1.200 Sp.gr, +/- 0.005 of acid to an end Volrage of 1.85 V/Cell.
06 Voltage / Cell at the end of full charge
07 Higher Recharging current under Constant Potential charging is allowed subject to controlling the temperature within 55 Deg C. Most preferred Temperature is within 43 Deg C for deriving maximum life, Frequent recharging at a temperature above 43 Deg C would drastically bring down useful service life.
08 Intermediate 'AH' capacities like 250AH, 350 AH ..... etc., is not covered in IS 1651 and therefore in the above
tabulation. It can be supplied if required.
09 Above cells are assembled in Hard Rubber container.
10 The above data is subject to change any time without notice as we constantly endeavour to improve the performance.
11
Abbreviations used : TOL : Tolerance A : Ampere hrs./hr : Hours/hour
AH : Ampere Hour V : Volts L : Length
mm : Millimetre Approx. : Approximately W : Width
Kgs. : Kilograms VPC : Volts / Cells H : Height
    Sp.gr : Specific Gravity C : Centrigrade Deg. : Degree
POWER BUILD BATTERIES PVT. LTD
No 4-M, KIADB Industrial Area
Yedahalli Village, Dabaspet
Bangalore Rural Dist. 562 111
Karnataka, India.
Tele   :   9448281674 / 9148448317
+91 80 2773 5346 / 5347
Email   :   sales@powerbuildbatteries.com
info@powerbuildbatteries.com